Validation of EEMC MC Geometry
Abstract: Summary of tests performed to validate eemc geometry version 5.21.
ecalgeo.g version 5.21
- EEmc MC Geometry version 5.21
- Probe material distribution at phi=90 degrees
- Probe material distribution at phi=105 degrees
- SMD Problems at the sector boundary
- Likely need to set an air volume to kONLY='Many' to fix
- SOLUTION: Increase size of EXSG volume (logical volume which creates SMD planes)
ecalgeo.g version 5.22
- Probe material in 1 degree slices around sector 12 boundaries
- SMD planes show up in correct positions
- SMD spacer shows up in SMD plane notches
- Extra spacer material < 1E-4 radiation lengths in overlap of SMD and spacer region
- Probe material in 1 degree slices around sector 03 / 04 division
- SMD in correct positions
- SMD absent in the gap, as expected
- Current orientation of the SMD plane
- Looking at volumes using GDRAW(...)
- Looking at materials in each tracking step