Update 05.24.2019 -- Run 9 embedding: More Tracking Matching Quantities For Different Ranges of PtMc
[Recorded on 05.30.2019] Following up from
We're trying to figure out a mysterious dip in the reconstructed pTtrk distribution. It might have to do with how we match detector-level tracks to particle-level tracks, so we've been checking quantities that play into that process (see the above link). Here are the the nCommon (the no. of TPC hits for a given detector-level track which is common to a given particle-level track) and pTfrac (= pTmatch / pTmc) distributions for all pTmc and for pTmc > 8 GeV/c:
Hmmm... While the pTfrac ratio is not flat, but it's not really all that illuminating...