Tray 102 has a bad POS HV cable. It is behind the TPC support and cannot be repaired.
Run 10 start 58
end 10
Run 11 start 25
end 25
Run 12 start 95
end 95
Run 13 start 46 106
end 46 106
Run 14 start 20 22 35 103
end 20 22 35 78 103
Run 15 start 38 41
end 38 41
Run 16 start 105
end 105
Run 17 start 36 45 80
end 36 45 80 91 116
Run 18 start 8 43 116
end 2 8 40 43 116
Run 19 start 30 34 (water leak on THUB NW trays 21-50)
end 22 25 27 30 34 67 97
Run 20 start 22 25 67
end 8 22 25 48 64 67 88 101 118 119
Run 21 start 8 22 48 64 67 88 101 118 119
end 8 22 48 49 64 67 88 101 118 119
pp500/510 history:
Run 9 10 pb-1
11 37 pb-1
12 82 pb-1
13 300 pb-1
17 320 pb-1
22 400 pb-1 (BUR)
Current bad trays:
8 - 8:0 bunch id error, 8:1 missing
22 - no canbus
48 - 48:0,1 missing
49 - no canbus
64 - TDIG 59 no response
67 - may be ok now
88 - 88:0 missing
101 - 101:0 missing, 101:1 bunch id error
118 - bad LV connection, seems ok now
119 - 119:0 HPTDC 0x6 error
[geurts@tofcontrol ~]$ snmpwalk -v 2c -m +WIENER-CRATE-MIB -c guru tof-lvps1 snmpCommunityName
WIENER-CRATE-MIB::snmpCommunityName.public = STRING: "tof-pub"
WIENER-CRATE-MIB::snmpCommunityName.private = STRING: "tof-priv"
WIENER-CRATE-MIB::snmpCommunityName.admin = STRING: "admin"
WIENER-CRATE-MIB::snmpCommunityName.guru = STRING: "guru"
This page is intended to host information about TOF's high voltage equipment.
The A1534 is the HV Supply board that is inserted into our SY1527(MTD:SY4527 ).
Currently used boards(03/01/2016) for TOF + MTD: serial number and firmware version
TOF(counting from 0):
slot 1(-): 54, 3.01
slot 3(+): 56, 2.02
slot 5(-): 55, 2.02
slot 7(+): 57, 2.02
MTD(counting from 0):
slot 1(-): 66, 04.
slot 3(+): 69, 3.01
slot 5(-): 71, 04.
slot 7(+): 61, 03.
slot 9(-): 59, 3.01
Spare(-): serial number 58
Bad boards:
#59(Neg) - channel 3 bad (ch. 0-5) [occurred ~2/5/16 in SY4527 while in slot 1, was replaced with #66 on 2/17/16, then reinstalled in slot 9]
#66(Neg) - channel 3 bad (ch. 0-5) [occurred ~6/16/15 in SY1527LC spare while in slot 5, then installed and bl30,1 no data but reading back values when in slot 1 in 02/17/16]
-Email thread MTD BL 15-17 HV on MTDops 6/22-6/26/15.
-Not sure if this board was repaired between run15+16 and then failed again.
Spare:
#58(Neg) - possible bad channel 3 (ch.0-5). I think this was swapped in for #66 ~6/16/15(spare SY1257LC) and out for #71 ~2/02/16 (SY4527). Would have been in slot 5
Unaware of the positive spares available.
BTW: reoccurring issues on MTD BL15-17 from at least 1/17/2015 [slot 5 channel 3] and 5/11/2014, 1/31/2014...
Also some board repair history:
Forum: TOF sub-system forum
Re: HV boards in need for repair (Bertrand H.J. Biritz)
Date: 2010, Jul 27
From: W.J. Llope
Hi Bertrand, since there are so many bad boards now - Geary and I agree that we
should probably send them all in together a.s.a.p...
thanks, cheers,
bill
On Jul 26, 2010, at 7:34 PM, Bertrand H.J. Biritz wrote:
> Hi All,
>
> Just wanted to open the discussion on how to proceed with the HV board repairs.
>
> In total there are three boards in need of repair, with board 54 already having been sent in:
>
> Board 54: Channel 0 is arching [In use and fixed for TOF. Would explain the updated firmware.-joey ]
>
> Board 58: Channel 0 has ~130V offset and channel 3 no longer works [Could be a reoccurring issue with channel 3...?or explain why it failed, if it was the one swapped above-joey]
>
> Board 56: Channel 5 no longer works [In use on TOF--repaired.-joey]
>
> Board 58 is powering the East negative side of TOF (and MTD) while board 56 is for the East positive side of TOF (and MTD). We no longer have enough spares to make up for the lose of these boards.
>
> During last weeks TOF phone conference Geary said board 58 should be sent in for repair once the last noise rate data run was taken.
> Does the fact that an additional board is in need of repair change this and should board 56 be sent in at the same time as well?
>
> CAEN will be entering their three week summer holiday beginning of August. My unfounded guesstimation for getting the boards back is end of September at the earliest.
>
> Bertrand
>
>
> -------------------------------------------------------------
> Visit this STAR HyperNews message (to reply or unsubscribe) at:
> http://www.star.bnl.gov/HyperNews-star/get/startof/2362.html
>
Format: NPS [login protocol] (comment) plug: name (comment)
tofrnps[ssh] sample instruction: apc>olStatus all E000: Success 1: MTD THUB FANS 2: TOCK 3: THUB_LVPS PL512 LV supply, also powers VPD 4: ZDC_TCIM 5: unused 6: unused 7: unused 8: unused
tofpnps[ssh] A1: CAEN_HV A2: UPS (tofcontrol & systec?) A3: Start-box fans (VPD) A4: TOF_THUB_fans B1: tofcontrol_pc B2: can_if_1-8 B3: can_if_9-16 B4: unused
tofnps1[telnet] (LV for west trays) 1: trays_1-12_W1 2: trays_14-24_W2 3: trays_25-36_W3 4: trays_37-48_W4 5: trays_49-60_W5 6: empty 7: empty 8: empty
tofnps2[telnet] (LV for east trays) 1: trays_61-72_E1 2: trays_73-84_E2 3: trays_85-96_E3 4: trays_97-108_E4 5: trays_109-120_E5 6: empty 7: empty 8: stp_conc_1 (cf. trigger group)
mtdnps[telnet] 1: MTD LV 1: 25-6 2: MTD LV 2: BL 7-13, 24 3: MTD LV 3: BL 14-22 4: MTD-HV (CAEN)
etof-nps [telnet] Plug | Name | Password | Status | Boot/Seq. Delay | Default | -----+------------------+-------------+--------+-----------------+---------+ 1 | _12V_LVPS-A | (defined) | ON | 0.5 Secs | ON | 2 | _12V_LVPS-B | (defined) | ON | 0.5 Secs | ON | 3 | mTCA-P13-Backup | (defined) | ON | 0.5 Secs | ON | 4 | mTCA-P11-Primary | (defined) | ON | 0.5 Secs | ON | 5 | mTCA-P12-Primary | (defined) | ON | 0.5 Secs | ON | 6 | mTCA-P14-Backup | (defined) | ON | 0.5 Secs | ON | 7 | _12V_LV-RKP-Chas | (defined) | ON | 15 Secs | ON | 8 | RaspPi-LV-Cntrl | (defined) | ON | 15 Secs | ON | -----+------------------+-------------+--------+-----------------+---------+