BTOF Hardware
BTOF Hardware & Electronics
- Bad Tray History (Aug. 20, 2021)
Tray 102 has a bad POS HV cable. It is behind the TPC support and cannot be repaired.
Run 10 start 58
end 10
Run 11 start 25
end 25
Run 12 start 95
end 95
Run 13 start 46 106
end 46 106
Run 14 start 20 22 35 103
end 20 22 35 78 103
Run 15 start 38 41
end 38 41
Run 16 start 105
end 105
Run 17 start 36 45 80
end 36 45 80 91 116
Run 18 start 8 43 116
end 2 8 40 43 116
Run 19 start 30 34 (water leak on THUB NW trays 21-50)
end 22 25 27 30 34 67 97
Run 20 start 22 25 67
end 8 22 25 48 64 67 88 101 118 119
Run 21 start 8 22 48 64 67 88 101 118 119
end 8 22 48 49 64 67 88 101 118 119
pp500/510 history:
Run 9 10 pb-1
11 37 pb-1
12 82 pb-1
13 300 pb-1
17 320 pb-1
22 400 pb-1 (BUR)
Current bad trays:
8 - 8:0 bunch id error, 8:1 missing
22 - no canbus
48 - 48:0,1 missing
49 - no canbus
64 - TDIG 59 no response
67 - may be ok now
88 - 88:0 missing
101 - 101:0 missing, 101:1 bunch id error
118 - bad LV connection, seems ok now
119 - 119:0 HPTDC 0x6 error
- Electronics Documentation on old server (pending transition to drupal)
- Wiener PL512 Technical Manual
- default SNMP community names for all TOF and MTD power supplies: {tof-pub, tof-priv, admin, guru}:
[geurts@tofcontrol ~]$ snmpwalk -v 2c -m +WIENER-CRATE-MIB -c guru tof-lvps1 snmpCommunityName
WIENER-CRATE-MIB::snmpCommunityName.public = STRING: "tof-pub"
WIENER-CRATE-MIB::snmpCommunityName.private = STRING: "tof-priv"
WIENER-CRATE-MIB::snmpCommunityName.admin = STRING: "admin"
WIENER-CRATE-MIB::snmpCommunityName.guru = STRING: "guru" - power supply hostnames: see Tray Mapping documents